When the wire sits inside a device that touches a patient, consistency stops being a quality target and becomes the qualification itself — the hundredth spool must behave like the first.
The three requirements that decide whether the wire qualifies here.
Heating probes and analytical filaments are specified in hundredths of a millimetre. Diameter and ovality are reported per lot so the device calibration holds across builds.
Drawing lubricant or oxide left on the surface changes both heat transfer and biocompatibility review. Final degreasing and clean spooling are part of the delivery, not an extra.
A disposable heating device is designed around one resistance per metre. Lot-to-lot variation is what turns a validated design into a re-validation.
Starting points — final choice follows the device validation and the cleaning route.
| Application | Grade | Typical size | Why |
|---|---|---|---|
| Heating probe element | Ni80Cr20 | 0.05–0.30 mm | Fine gauge, stable resistance |
| Disposable heating device | Ni60Cr15 | 0.08–0.25 mm | Lower cost, adequate cycle life |
| Analytical instrument filament | Ni200 / Ni201 | 0.05–0.20 mm | High purity, low outgassing |
| Sensor and electrode lead | Ni200 | 0.10–0.40 mm | Consistent EMF, weldable |
| Precision resistance component | Constantan CuNi44 | 0.05–0.30 mm | Flat resistance against temperature |
| Spring and contact part | Ni201 / Monel 400 | 0.15–0.60 mm | Corrosion resistance, formability |
We supply the alloy and its mill certificate; we are a wire mill, not a device manufacturer, so we do not issue biocompatibility certification for a finished device. What we can provide is full chemistry, traceability and a documented clean-surface route so your own validation has a defined input.
On 0.05–0.30 mm nichrome and nickel wire we routinely hold the tolerances quoted on the product page, with diameter and ovality reported per lot. If your probe design needs tighter than our standard band, send the drawing — we will confirm what is achievable rather than quote optimistically.
Yes. Final drawing is followed by degreasing, and spools are packed clean. For devices where residue matters, state the requirement on the order so the cleaning route is written into the confirmation.
Resistance per metre is reported with each lot and we can work to a declared window rather than a typical value. Tell us the window your design assumes; if it falls outside what the alloy naturally gives, we will say so before you order.
Gauge, resistance window, cleaning requirement and annual volume — with those we can quote a wire that keeps your validation valid.