Skip to content
Home / Industries / Industrial furnaces & heat treatment
Industry 01

Industrial furnaces & heat treatment

Elements that hold their resistance through ten thousand cycles, fixtures that do not sag, and a supplier who can tell you the expected life before you build the furnace.

What this application demands

The three requirements that decide whether the wire works here.

Repeatable resistance

Element wattage has to stay inside the tolerance your controller and process can absorb, lot after lot.

Life at temperature

Oxide scale growth, sag and grain growth set the replacement interval — not the data sheet maximum.

Documented lots

Traceability from melt to spool, with the certificate formats your quality system expects.

Recommended grades and sizes

Starting points — the final choice follows the atmosphere, cycle and geometry.

ApplicationGradeTypical sizeWhy
Element wire0Cr27Al7Mo21.53 µΩ·m, 1,400 °CRadiant tube, ceramic fibre modules
Element wire0Cr25Al51.42 µΩ·m, 1,300 °CRoller hearth, tempering, annealing
Element wireNi80Cr201.09 µΩ·m, 1,200 °CWhere ductility after service matters
Fixture wireInconel 601Oxidation to 1,200 °CTrays, baskets, mesh belts
Support wireInconel 600Good creep to 1,000 °CElement supports, hooks

Products used in this industry

Asked by engineers in this industry

Why do our elements fail at the support points?

Usually local overheating from poor contact rather than a grade problem. Supports should be spaced to the sag data of the specific grade, and the wire should be free to expand. Send a photo and the element drawing and we will check it.

Can you supply wire in the annealed condition for winding?

Yes, annealed and soft for winding, then the element is fired to develop the alumina or chromia scale. Tell us the winding diameter so we do not ship a temper that cracks at the bend.

Do you have sag data above 1,200 °C?

We quote creep and sag for the FeCrAl grades at the service temperature you give, based on our own furnace trials. It is the number element designers actually need, and it is not on a typical data sheet.

Tell us the application, not just the grade.

Service temperature, atmosphere, cycle time and joint design — with those four numbers we can recommend a grade and size with the life you need.